You can not select more than 25 topics Topics must start with a letter or number, can include dashes ('-') and can be up to 35 characters long.

98 lines
2.6 KiB

4 days ago
[Board]
PortName=COM5
BaudRate=115200
ReadTimeout=5000
PreConnectCommand=x00o
ConnectCommand=x00c_001101:owt28006727ea97c7801
ReadIdCommand=x00c_001101:ow2800326003e
PostReadIdCommand=x00o
CalDefaultCommand=x00c_001001:owt28006727ea97c7801
EndToken=<end>
DtrEnable=false
RtsEnable=false
[BarcodeScanner]
Enabled=true
PortName=Auto
BaudRate=9600
ReadTimeout=500
IdleCommitMilliseconds=250
DtrEnable=true
RtsEnable=true
[StartSignal]
; USB-6501
Enabled=true
Connection=Ni6501
PhysicalChannel=Dev1/port0/line0
ActiveState=Low
PollIntervalMilliseconds=50
; 0 = wait until the equipment start button is pressed, without a time limit.
TimeoutMilliseconds=0
PostSignalDelayMilliseconds=2000
RequireInactiveBeforeStart=true
[Equipment]
; V 출력: Keysight 34465A DMM 값
; A 출력: Keysight E36233A Power Supply CH1 Current 값
; USB 장비는 Keysight Connection Expert 또는 NI MAX에서 보이는 VISA 주소를 Resource
Timeout=5000
SettleMilliseconds=300
PreBoardCommand=VOLT 5, (@2);OUTP ON, (@2)
PreBoardDelayMilliseconds=2000
LogoutCommand=OUTP OFF, (@1)
; 34465A DMM
VoltageConnection=LAN
VoltageResource=
VoltageIdnMatch=34465A
VoltageHost=192.168.10.13
VoltagePort=5025
VoltageSetupCommand=
VoltageReadCommand=MEAS:VOLT:DC?
; Separate resistance meter. Change its address/commands here.
; Read after V/current and CH1 output OFF. Normal response: Ohm -> kOhm; overload: 999 + OL status.
; Resistance is required for inspection; Disabled stops the inspection with an error.
ResistanceConnection=LAN
ResistanceResource=
; Optional model identifier to validate with *IDN? (leave blank until the model is known).
ResistanceIdnMatch=
ResistanceHost=192.168.10.34
ResistancePort=5025
ResistancePortName=
ResistanceBaudRate=115200
ResistanceTerminator=LF
ResistanceReadCommand=MEAS:RES?
ResistanceSetupCommand=
; Query the CURRENT power supply to confirm CH1 output is OFF before resistance measurement.
ResistancePowerOffQuery=OUTP? (@1)
ResistanceSettleMilliseconds=300
; E36233A Power Supply
CurrentConnection=LAN
CurrentResource=
CurrentIdnMatch=E36233A
; Change this to the E36233A LAN IP if the instrument uses a different address.
CurrentHost=192.168.10.12
CurrentPort=5025
CurrentPortName=
CurrentBaudRate=9600
CurrentTerminator=LF
CurrentSetupCommand=OUTP ON, (@1)
CurrentCleanupCommand=OUTP OFF, (@1)
CurrentReadCommand=MEAS:CURR? (@1)
; COM 포트로 잡히는 장비 예시:
; VoltageConnection=Serial
; VoltagePortName=Auto
; VoltageBaudRate=115200
; LAN 장비 예시:
; VoltageConnection=Tcp
; VoltageHost=192.168.0.10
; VoltagePort=5025
; E36233A 파워서플라이에서 CH1 전압까지 읽고 싶을 때 예시:
; VoltageReadCommand=MEAS:VOLT? CH1